Navigate the deposition interface
Use the left-hand navigation panel to move among the different data entry pages.
- Yellow folder icons indicate folders that contain related data entry pages. Click an icon to open or close the folder.
- Red exclamation icons represent pages that require the input of mandatory data. These mandatory items will appear in red. We recommend that you also complete as many non-mandatory fields as possible.
- Green check marks indicate that all mandatory data items on a page have been entered.
Figure: DepUI page status indicators.
Data can be reviewed and edited on each individual entry page.
- A field with a red box and warning must be corrected before submission.
- A field with a yellow box indicates an unusual value — check it.
Figure: Navigation icons and completeness bars in the deposition interface.
The submission progress tracker at the top left of the screen shows your progress. As you enter data, the list of minimum mandatory items required for submission is automatically checked by the system. In the left-hand navigation panel, two bars indicate the percentage of completeness of the deposition:
- The Submit button is shaded by the percentage of mandatory data items supplied. Clicking this bar shows a list of the missing mandatory items. The entry can be submitted when the button is completely green.
- The Data Supplied button is shaded by the percentage of all possible data items that have been provided.
Figure: Submission progress trackers.
General metadata
Macromolecules/sequence
- Open a molecule page under the Macromolecules folder.
- Provide a biological molecule name, select how the molecule was obtained, and specify the source organism.
- Review the macromolecule source summary information.
- Check the sequence consistency result (author sample sequence vs. coordinate sequence).
- If there is a discrepancy, provide either a corrected sample sequence or a new coordinate file.
Figure: Sequence entry and alignment check.
Assembly
The Assembly page captures the quaternary structure of the deposited model.
For X-ray structures, the biological assembly may be identical to the asymmetric unit, a subset requiring symmetry operations, or composed of multiple asymmetric units.
Figure: Biological assembly relative to the asymmetric unit.
Follow these steps to provide the quaternary structure information:
- Describe the assembly in Assembly details.
- Add experimental evidence when available.
- Define chain-level composition under Chains and matrices.
- Select Yes if all AU chains are included; otherwise specify chain IDs.
- Select Yes if no symmetry is required (unitary matrix applied); otherwise provide the 3×4 matrix.
- Use + to add additional assemblies.
Figure: Assembly input form.
-
Review assemblies in the Mol* 3D viewer provided on the Assembly page:
- In the right-side panel, open Structure > Type and select Assembly. If more than one assembly is available, an Asm Id selector appears below, where you can switch between assemblies. Select Model to return to the deposited model view.
Figure: Assembly review in Mol*.
Ligands
Open Ligands to review ligands extracted from coordinates and matched against the Chemical Component Dictionary (CCD).
- If an exact match is found, no further action is required.
- If a close match is found, review the possible matches suggested by the system.
-
If no match is found in the CCD, or if there is a chemical difference between the target ligand and the closest match, provide one of the following:
- the CCD code of an alternative ligand present in the CCD;
- a SMILES or InChI string for the ligand; or
- a chemical diagram of the ligand.
A descriptor or diagram should include complete stereochemical information.
- Optionally, upload a refinement monomer library file.
- If there is a covalent bond between the ligand and protein, please provide details about the starting molecule and leaving group.
- Indicate which molecule is the focus of the study (ligand of interest, LOI).
Figure: Ligand identification against the CCD. Descriptors/diagrams should include complete stereochemistry. For covalent ligand-protein bonds, provide the starting molecule and leaving groups.
Figure: Ligand summary and instance-level CCD comparison.
Method-specific metadata
NMR-specific fields
- For NMR depositions, it is best to enter information starting from the top of the left-hand navigation panel and working downward sequentially, page by page, as some values on later pages (lower on the navigation panel) depend on information entered on earlier pages (higher on the navigation panel).
- In particular, the chemical shift connection page cannot be completed until the mandatory data items in the NMR experimental section and NMR software section have been completed.
The chemical shift connection page links data used to assign the chemical shifts with information contained in other NMR sections,
i.e., chemical shift file names, chemical shift references, NMR samples, sample conditions, NMR experiments, and software.
- In addition, the spectral peak list section becomes mandatory when NMR peak list files are uploaded.
3DEM-specific fields
Sequence information
For map-only EMDB depositions (no coordinates provided), sequence information on the Macromolecules page is optional (UniProt/GenBank references may still be provided).
Sample information
Sample information is collected hierarchically. For example:
Overall sample: ribosome
-
Component: 50S large ribosomal subunit
- Subcomponent: 5S rRNA
- Subcomponent: 23S rRNA
- Subcomponent: SeC6
- Subcomponent: 50S ribosomal protein L4
-
Component: 30S small ribosomal subunit
- Subcomponent: 16S rRNA
- Subcomponent: eIF2
- Subcomponent: 30S ribosomal protein S1
- Subcomponent: 30S ribosomal protein S2
NOTE: Subcomponents can be added and/or deleted as necessary, but deleting a component also deletes all of its subcomponents.
Complete the overall sample (and subcomponent) details before the EM experiment page. Work through those sections top-down; most contain mandatory items.
Experimental information
The “EM experiment” page in the deposition interface contains five sections. Each section includes data items that link to other experimental sections and to the overall sample description and its subcomponents (see the previous section).
Figure: EM experiment section.
Complete the five experimental sections sequentially, starting at the top.
Figure: Recommended order for 3DEM experimental metadata. Use + where multiple sessions, detectors, reconstructions, or fittings apply.
Details regarding each subsection follow. Please note that most of the experimental sections contain mandatory items that must be filled in before the deposition can be finalized and submitted.
- Specimen preparation. Information about sample vitrification, staining, embedding, and shadowing, as well as details about the sample grid and its pretreatment, film support, and crystal formation (where applicable).
- Microscopy. Comprehensive information about the microscope(s) used for data collection, including electron source, specimen holder, energy filters, etc., as well as the microscope settings and other parameters used for each imaging session. Multiple imaging sessions can be added by clicking the “+” button at the bottom of the “Microscopy” page.
- Image recording. Information about the detector(s) or other device(s) used for image recording, including both the physical properties of the detector and the manner in which the images were collected, e.g., data handling during and directly after capture, number of images, rate of movie frame collection, etc. As in the “Microscopy” section, use the “+” button if multiple detectors were used for image recording.
- Reconstruction. Details of the method or methods used to generate three-dimensional map(s) from two-dimensional images, including particle selection, classification, alignment, angular assignment, and reconstruction. Information about multiple reconstructions can be included.
- Fitting interpretation. Information about the fitting of pre-existing atomic coordinates and/or ab initio models to the map, if applicable. Multiple fitting instances can be added (by clicking the “+” button at the bottom of the page) and each instance can accommodate multiple starting models if necessary. Additional details include the software and settings for any model building, fitting, and/or refinement used to generate the final model.