Tour of OneDep Deposition System

This page offers a guided walkthrough of preparing files, starting a deposition session, uploading data, completing metadata, and submitting to the wwPDB.

Tour of OneDep Deposition System

Overview

The deposition process follows six stages. Work through them in order; later steps depend on files and choices made earlier.

Deposition process stages: prepare, start, upload, metadata, submit, communicate
Figure: End-to-end OneDep deposition pipeline.

At a glance, the experimental method determines which files you need to upload and which accession codes are issued:

Experimental method and accession codes
Required files by experimental method
Figure: Method choice drives required files and accession codes (PDB, EMDB, BMRB).

1. Prepare files

Prepare model files in PDBx/mmCIF format

  • Prepare all required coordinate and experimental data files before starting your deposition.
  • PDBx/mmCIF is the official working format of the wwPDB and is recommended for all coordinate depositions whenever possible. For X-ray crystallography depositions, PDBx/mmCIF coordinate files are required.
  • Most current refinement programs (e.g., Phenix, REFMAC, and BUSTER) generate deposition-ready PDBx/mmCIF files automatically. If needed, use pdb_extract to convert PDB-format files.
  • Review the method-specific file requirements for X-ray, 3DEM, or NMR before starting.

Harvest metadata using pdb_extract

Use pdb_extract to:

  • Harvest data in PDBx/mmCIF format from structure determination programs
  • Convert PDB-format files to PDBx/mmCIF format
pdb_extract workflow
Figure: pdb_extract harvests or converts data, then hands off to OneDep.
pdb_extract homepage
Figure: pdb_extract homepage.

Prepare method-specific files

X-ray

Mandatory files:

  • Coordinates in mmCIF format
  • Structure factor file (mmCIF or MTZ) including h, k, l, F, SigmaF (and/or I and SigmaI) and test flags

Definitions and format are described in Appendix B of the wwPDB Processing Procedures.

3DEM

Mandatory files:

  • File: Primary map (.mrc or .ccp4 format; depositors may use gzip or bzip2 compression)
    • Metadata: voxel size and recommended contour level
  • File: Half maps (as used for FSC calculation; two non-identical maps must be uploaded)
    • Metadata: voxel size and recommended contour level
    • Half maps must be uploaded for SPA, STA, and helical 3DEM depositions.
    • Half maps should remain unmodified from their original output in the 3D refinement protocol used.
  • File: Image of the map (500 × 500 pixels in .jpg, .png, etc. format) for public display
    • The image must show the entry's density.

Upload of these additional files is encouraged by EMDB:

  • File: FSC curve supporting the resolution of the primary map derived from the half maps
    • Uploaded as XML and output from common 3D reconstruction software
  • File: Additional maps
    • For example: maps with varying B-factors, density modification, etc.

All of these files are made publicly available upon release of the EMDB entry.

NMR

Mandatory files:

  • Coordinates in PDB or mmCIF format (all models should be superimposed)
  • Restraints
  • Chemical shifts

Encouraged: peak lists.

2. Start deposition session

Log in with ORCID

  • Go to the deposition page at https://deposit.wwpdb.org/deposition.
  • Click “Sign in with ORCID”.
    OneDep login panel
    Figure: Login panel when starting a new deposition.
  • Enter your ORCID iD and password, or sign in to ORCID through one of the alternative methods (institution, Google, or Facebook).
    ORCID sign-in page
    Figure: Sign in with ORCID iD.
  • OneDep shows a summary table of the entries in which your ORCID iD has been set as a contact author.
  • Click a deposition ID to open that entry in the deposition interface without entering its deposition ID or password.
  • You can sort and filter your existing entries in this summary table.
    ORCID summary table
    Figure: Summary table of the entries in which your ORCID iD has been set as a contact author.

Start a new deposition

  • First, verify your email address (a one-time operation).
  • Enter your email address in the left-side panel (this address does not have to be the same as the one registered with ORCID).
  • Click “Verify”.
    Verify your email
    Figure: Verify your email.
  • You should receive an email with a link to verify your email address.
  • Click the link.
    Email verification link
    Figure: Verify your email (continued).
  • A drop-down menu will appear to select your country/region.
  • Select your country/region and you will be redirected to the wwPDB member’s deposition site (RCSB PDB, PDBe, or PDBj) corresponding to your location.
    Select your country/region
    Figure: Provide your country/region.
  • Fill in the form (email address, experimental method, etc.).
  • To select the proper experimental method, see Select experimental type below.
  • The deposition password is auto-generated and will be sent by email.
  • Click “Start deposition”.
    New deposition form
    Figure: Fill in the form and start deposition.
  • You will be redirected to the new session.
  • Now you can log in and start the deposition.

NOTE:

  • Adding a contact author’s ORCID iD in “Admin > Contact information” will grant that author access to the current deposition.
  • Check ORCID iDs carefully when adding additional contact authors.

Select experimental type

At the start of the deposition, the depositor will be asked to provide information about the experimental methods used to determine the structure.

X-ray

Select X-ray diffraction.

3DEM

Select a subtype from the list:

  • Helical
  • Single particle
  • Subtomogram averaging
  • Tomography
3DEM with coordinates
  • Are you depositing coordinates? → Yes
  • Has the associated map been deposited previously?
    • No → issue a new EMDB ID
    • Yes → enter the existing EMDB ID

PDB and EMDB accession checkboxes are set automatically from your answers.

3DEM map-only (no coordinates)

Are you depositing coordinates? → No, experimental data only

EMDB is the only requested accession code.

3DEM start form
Figure: 3DEM start form: method, coordinates, and prior-map choices determine accession codes.
Composite maps

Choose Yes for ‘Is this a composite map deposition?’

For a composite map deposition, make sure to deposit separately:

  • Each of the corresponding focused refinement maps
  • The low-resolution consensus map supporting the overall structure

Refer to the EMDB composite map deposition guide.

Separate depositions for composite maps
Figure: Composite map depositions require separate depositions for focused and consensus maps.

NMR

Select Solution NMR or Solid-state NMR.

NMR with coordinates
  • Are you depositing coordinates? → Yes
  • Have the associated NMR experimental data been deposited previously?
    • No → issue a new BMRB ID
    • Yes → enter the existing BMRB ID
NMR experimental data only
  • Are you depositing coordinates? → No, experimental data only (issue BMRB ID only)
  • Click ‘Deposit NMR data at BMRB’ to go to the BMRB start page.

If you later want to deposit coordinates, this will require a new, separate PDB-only deposition.

NOTE: If multiple experimental methods were involved in structure determination and refinement, please select all that apply.

3. Upload files

General upload process

  • Log in with the Deposition ID and password (left-hand panel). The Deposition ID appears at the top after login. Open File upload in the navigation panel, upload coordinate and experimental files, and assign file types from the drop-down menus.
  • After the upload starts, initial validation runs; you will receive an email when it finishes. Reports appear under Validation Reports.
  • Replace files at any time before submission via Re-upload files.
  • Review the Upload Summary carefully — it shows what was uploaded and how the uploaded data were interpreted.

NMR upload checks

  • Checks that all models have identical chemistry (the same atoms, homogeneous).
  • Checks chemical shift values for validity.
  • Checks atom nomenclature consistency between chemical shift and coordinate files.

Problems are reported in two ways:

  • Warnings appear in the file-format validation window (e.g., shifts outside acceptable ranges) — review and verify or correct them.
  • Errors appear on the diagnostic screen after Populate/Repopulate and on the Upload Summary; they often flag nomenclature issues that must be fixed with new files before the deposition can be completed.

3DEM upload checks

  • Checks that the contour level, voxel size, and a brief description are provided for each map.
  • Provided values are checked against the uploaded maps.
  • To ensure accurate validation, if a model has been built, please provide the exact pixel spacing used during model building.
3DEM file upload page
Figure: 3DEM upload: missing map metadata and coordinates block progress; FSC upload is encouraged.

Deposition of several related entries

Based on a previous entry

When depositing a related structure, the OneDep File upload page offers Based on a previous wwPDB deposition. This lets you copy selected metadata from a previous wwPDB entry into your new deposition.

Based on a previous wwPDB deposition option
  1. Open File upload in your deposition session at deposit.wwpdb.org.
  2. Under ‘Based on a previous wwPDB deposition’, select Yes.
  3. Enter the previous deposition ID (D_xxxxxxxxxx) and authenticate with the related entry’s password, or sign in with ORCID if the entry is yours.
  4. Select the metadata categories to import (for example authors, citation, funding, keywords, macromolecules, or method-specific experimental information).
  5. Upload your new coordinate, map, and/or data files, then process them as usual.
  6. After processing, the Summary page shows which categories were imported, skipped, or blocked, with a detailed import log.
Related entry import workflow
Figure: Related-entry import copies metadata only; data files are never copied. Method-specific options require matching techniques (for EM, the reconstruction sub-method must also match).

What can be imported

Select metadata categories to import
  • Typical categories include authors and contact information, entry keywords, citation information, funding information, macromolecules, and X-ray, NMR, or EM experimental information. Method-specific options appear only when the previous and current depositions use compatible experimental methods. For EM, the reconstruction sub-method must also match to import EM experimental information.
  • Coordinates, maps, and structure factors are not copied from the previous entry: you always upload new data files for the current deposition.
Metadata categories for EM and X-ray depositions
Figure: Related-entry import (EM and X-ray examples). Greyed items are incompatible with the current method.

pdb_extract

You can also use pdb_extract to prepare a method-specific template and reuse it for entries that share common metadata.

pdb_extract metadata template
Figure: pdb_extract Step 1: prepare a reusable metadata template.

4. Enter metadata using the deposition interface

Navigate the deposition interface

Use the left-hand navigation panel to move among the different data entry pages.

  • Yellow folder icons indicate folders that contain related data entry pages. Click an icon to open or close the folder.
  • Red exclamation icons represent pages that require the input of mandatory data. These mandatory items will appear in red. We recommend that you also complete as many non-mandatory fields as possible.
  • Green check marks indicate that all mandatory data items on a page have been entered.
Page status indicators
Figure: DepUI page status indicators.

Data can be reviewed and edited on each individual entry page.

  • A field with a red box and warning must be corrected before submission.
  • A field with a yellow box indicates an unusual value — check it.
Field warnings in the deposition interface
Figure: Navigation icons and completeness bars in the deposition interface.

The submission progress tracker at the top left of the screen shows your progress. As you enter data, the list of minimum mandatory items required for submission is automatically checked by the system. In the left-hand navigation panel, two bars indicate the percentage of completeness of the deposition:

  • The Submit button is shaded by the percentage of mandatory data items supplied. Clicking this bar shows a list of the missing mandatory items. The entry can be submitted when the button is completely green.
  • The Data Supplied button is shaded by the percentage of all possible data items that have been provided.
Submission progress trackers
Figure: Submission progress trackers.

General metadata

Macromolecules/sequence

  • Open a molecule page under the Macromolecules folder.
  • Provide a biological molecule name, select how the molecule was obtained, and specify the source organism.
  • Review the macromolecule source summary information.
  • Check the sequence consistency result (author sample sequence vs. coordinate sequence).
  • If there is a discrepancy, provide either a corrected sample sequence or a new coordinate file.
Sequence entry and alignment check
Figure: Sequence entry and alignment check.

Assembly

The Assembly page captures the quaternary structure of the deposited model.

For X-ray structures, the biological assembly may be identical to the asymmetric unit, a subset requiring symmetry operations, or composed of multiple asymmetric units.

Biological assembly
Figure: Biological assembly relative to the asymmetric unit.

Follow these steps to provide the quaternary structure information:

  • Describe the assembly in Assembly details.
  • Add experimental evidence when available.
  • Define chain-level composition under Chains and matrices.
  • Select Yes if all AU chains are included; otherwise specify chain IDs.
  • Select Yes if no symmetry is required (unitary matrix applied); otherwise provide the 3×4 matrix.
  • Use + to add additional assemblies.
Assembly input form
Figure: Assembly input form.
  • Review assemblies in the Mol* 3D viewer provided on the Assembly page:
    • In the right-side panel, open Structure > Type and select Assembly. If more than one assembly is available, an Asm Id selector appears below, where you can switch between assemblies. Select Model to return to the deposited model view.
Assembly review in Mol*
Figure: Assembly review in Mol*.

Ligands

Open Ligands to review ligands extracted from coordinates and matched against the Chemical Component Dictionary (CCD).

  • If an exact match is found, no further action is required.
  • If a close match is found, review the possible matches suggested by the system.
  • If no match is found in the CCD, or if there is a chemical difference between the target ligand and the closest match, provide one of the following:
    • the CCD code of an alternative ligand present in the CCD;
    • a SMILES or InChI string for the ligand; or
    • a chemical diagram of the ligand.
    A descriptor or diagram should include complete stereochemical information.
  • Optionally, upload a refinement monomer library file.
  • If there is a covalent bond between the ligand and protein, please provide details about the starting molecule and leaving group.
  • Indicate which molecule is the focus of the study (ligand of interest, LOI).
Ligand identification
Figure: Ligand identification against the CCD. Descriptors/diagrams should include complete stereochemistry. For covalent ligand-protein bonds, provide the starting molecule and leaving groups.
Ligand summary
Ligand instance details
Instance-level CCD comparison
Figure: Ligand summary and instance-level CCD comparison.

Method-specific metadata

NMR-specific fields

  • For NMR depositions, it is best to enter information starting from the top of the left-hand navigation panel and working downward sequentially, page by page, as some values on later pages (lower on the navigation panel) depend on information entered on earlier pages (higher on the navigation panel).
  • In particular, the chemical shift connection page cannot be completed until the mandatory data items in the NMR experimental section and NMR software section have been completed. The chemical shift connection page links data used to assign the chemical shifts with information contained in other NMR sections, i.e., chemical shift file names, chemical shift references, NMR samples, sample conditions, NMR experiments, and software.
  • In addition, the spectral peak list section becomes mandatory when NMR peak list files are uploaded.

3DEM-specific fields

Sequence information

For map-only EMDB depositions (no coordinates provided), sequence information on the Macromolecules page is optional (UniProt/GenBank references may still be provided).

Sample information

Sample information is collected hierarchically. For example:

Overall sample: ribosome

  • Component: 50S large ribosomal subunit
    • Subcomponent: 5S rRNA
    • Subcomponent: 23S rRNA
    • Subcomponent: SeC6
    • Subcomponent: 50S ribosomal protein L4
  • Component: 30S small ribosomal subunit
    • Subcomponent: 16S rRNA
    • Subcomponent: eIF2
    • Subcomponent: 30S ribosomal protein S1
    • Subcomponent: 30S ribosomal protein S2

NOTE: Subcomponents can be added and/or deleted as necessary, but deleting a component also deletes all of its subcomponents.

Complete the overall sample (and subcomponent) details before the EM experiment page. Work through those sections top-down; most contain mandatory items.

Experimental information

The “EM experiment” page in the deposition interface contains five sections. Each section includes data items that link to other experimental sections and to the overall sample description and its subcomponents (see the previous section).

EM experiment section in the navigation panel
Figure: EM experiment section.

Complete the five experimental sections sequentially, starting at the top.

Recommended order for 3DEM experimental metadata
Figure: Recommended order for 3DEM experimental metadata. Use + where multiple sessions, detectors, reconstructions, or fittings apply.

Details regarding each subsection follow. Please note that most of the experimental sections contain mandatory items that must be filled in before the deposition can be finalized and submitted.

  • Specimen preparation. Information about sample vitrification, staining, embedding, and shadowing, as well as details about the sample grid and its pretreatment, film support, and crystal formation (where applicable).
  • Microscopy. Comprehensive information about the microscope(s) used for data collection, including electron source, specimen holder, energy filters, etc., as well as the microscope settings and other parameters used for each imaging session. Multiple imaging sessions can be added by clicking the “+” button at the bottom of the “Microscopy” page.
  • Image recording. Information about the detector(s) or other device(s) used for image recording, including both the physical properties of the detector and the manner in which the images were collected, e.g., data handling during and directly after capture, number of images, rate of movie frame collection, etc. As in the “Microscopy” section, use the “+” button if multiple detectors were used for image recording.
  • Reconstruction. Details of the method or methods used to generate three-dimensional map(s) from two-dimensional images, including particle selection, classification, alignment, angular assignment, and reconstruction. Information about multiple reconstructions can be included.
  • Fitting interpretation. Information about the fitting of pre-existing atomic coordinates and/or ab initio models to the map, if applicable. Multiple fitting instances can be added (by clicking the “+” button at the bottom of the page) and each instance can accommodate multiple starting models if necessary. Additional details include the software and settings for any model building, fitting, and/or refinement used to generate the final model.

5. Validate, review & submit

Check mandatory fields

When every page shows a green check mark, the Submit deposition button becomes fully green, and the entry can be submitted.

Check and approve the preliminary validation report

On the Validation Reports page, download and review the preliminary validation report, then indicate acceptance. The “Accept” button appears once the report has been downloaded.

Download the validation report
Figure: Download, review, and accept the preliminary validation report.

Accept terms and conditions

Agree to the Terms and Conditions on the Summary & conditions page before submission.

Final checks before submission
Figure: Final checks before submission.

6. Communication

Before session creation

For common questions, refer to the deposition FAQ.

For additional questions, email us at deposit-help@mail.wwpdb.org.

After session creation

Use the Communication page for all correspondence with the wwPDB. Messages related to the deposition are stored there. Processed files and validation reports from biocuration staff are available on the Communication page (as attachments) and on the Review page.

Communication and Review pages in the navigation panel
Figure: Location of the Communication and Review pages on the left-side menu of the deposition interface.

back to top