For NMR-specific Depositions:
Deposition start page
At the start of deposition, the depositor will be asked to provide information about the experimental methods employed to determine the structure.
For an NMR deposition that includes a coordinate file, select "Solution NMR" or "Solid-state NMR" as the Experimental Method. Once "Solution NMR" or "Solid-state NMR" has been selected as the Experimental Method, you will see questions about whether you are depositing coordinates and/or experimental data. After you answer the questions, the PDB and BMRB check boxes will automatically be checked for the appropriate accession codes. Press the "Start deposition" button to initiate a deposition session.
For an NMR deposition that does not include a coordinate file, select "Solution NMR" or "Solid-state NMR" as the Experimental Method and you will then be asked "Are you depositing coordinates with this submission?". Select "No, experimental data only", and you will see that BMRB is the only requested accession code, and a "Deposit NMR data at BMRB" button will appear at the bottom of the screen. Once you click the button, you will then be re-directed to the BMRB deposition start page. Please note that if you make a BMRB-only deposition, later deposition of associated coordinates will require that an additional, new PDB-only deposition be made.
File upload requirements
Upload of these files is mandatory:
- Coordinates
- Restraints
- Chemical shifts
Depositors are encouraged to also upload the following files:
File upload checks for NMR depositions
During file upload, the following checks are performed:
- Consistency checks are performed on the coordinate file to make sure each model has the same chemistry (identical atoms).
- Chemical shift value checks are performed on the chemical shift file.
- Atom nomenclature checks are performed on the chemical shift and coordinate files.
If there are any warnings or errors generated by these checks, they will be reported as follows:
Warning messages: Warning encountered upon file upload will be presented in the "File format validation for model coordinates and data files" window. For NMR entries, warning messages provide information about chemical shift values outside of acceptable ranges. Warning messages are provided for depositors to review and either verify or correct as appropriate.
Error messages: Errors encountered upon file upload will be presented in two places: (1) on the diagnostic screen (headed by a graphic of red gears) that appears after the "Populate" or "Repopulate" button on the "File upload" page has been pressed, and (2) on the "Upload Summary" page of the deposition interface. For NMR entries, error messages highlight atom nomenclature issues that must be corrected. If an error is present, new coordinate and/or chemical shift files must be uploaded before the deposition can be completed.
Entering NMR Data into the deposition interface
For NMR depositions, it is best to enter information starting from the top of the left-hand navigation panel and working downward sequentially, page by page, as some values on later pages (lower on the navigation panel) are dependent upon information entered on earlier pages (higher on the navigation panel).
In particular, the chemical shift connection page cannot be completed until after mandatory data items in the NMR experimental section and NMR software section have been completed. The chemical shift connection page links data used to assign the chemical shifts with information contained in other NMR sections, i.e., chemical shift files names, chemical shift references, NMR samples, sample conditions, NMR experiments, and software.
In addition, the spectral peak list section becomes mandatory when NMR peak list files are uploaded.
For Electron Microscopy Volume Map Depositions:
File upload requirements
Upload of the following files is mandatory:
- Primary map (.mrc or .ccp4 format, may use gzip or bzip2 compression) along with voxel size and recommended contour level
- Half maps (as used for FSC calculation; two maps must be uploaded). Half-maps must be uploaded for SPA, STA, and Helical 3DEM depositions. These half-maps should remain unmodified from their original output in the 3D refinement protocol used.
- Image of the map (500 x 500 pixels in .jpg, .png, etc. format)
Upload of these additional files is encouraged by EMDB:
- Additional maps
- FSC curves
- Layer line data
- Structure factor data
All of these files are made publicly available upon release of the EMDB entry.
Macromolecules page for EMDB map-only deposition
Depositors may provide sample sequence information along with appropriate UniProt and/or GenBank references. For a map-only deposition (no coordinates provided), sequence information is optional.
Sample information for an Electron Microscopy experiment
Information about the sample used in an electron microscopy experiment and about its source(s) is collected in a hierarchical fashion. An example is provided below:
-
Overall sample description: ribosome
-
subcomponent: 50S large ribosomal subunit
- subcomponent: 5S rRNA
- subcomponent: 23S rRNA
- subcomponent: SeC6
- subcomponent: 50S ribosomal protein L4
-
subcomponent: 30S small ribosomal subunit
- subcomponent: 16S rRNA
- subcomponent: eIF2
- subcomponent: 30S ribosomal protein S1
- subcomponent: 30S ribosomal protein S2
NOTE: Subcomponents can be added and/or deleted as necessary, but deletion of a subcomponent will result in deletion of all child subcomponents (e.g., deletion of b. from the example above will also delete i., ii., iii., and iv.).
Experimental information
There are five sections in the "EM experiment" folder in the deposition interface. Within each of these sections are data items that link to other experimental sections as well as to back to the overall sample description and its subcomponents (see previous section). As such, it is recommended that the overall sample description and any necessary subcomponents be completed prior to the entry of experimental information into the "EM experiment" section. In addition, it is also recommended that the experimental sections be completed sequentially from the top down.
Details regarding each subsection follow. Please note that there are mandatory items in most of the experimental sections that must be filled in before the deposition can be finalized and submitted.
- Specimen preparation. This section comprises information regarding sample vitrification, staining, embedding, and shadowing, as well as details about the sample grid and its pretreatment, film support, and crystal formation (where applicable).
- Microscopy. This section comprises comprehensive information regarding the microscope(s) used for data collection, including electron source, specimen holder, energy filters, etc., as well as the microscope settings and other parameters used for each imaging session (magnification, defocus, alignment procedure, etc.). Multiple imaging sessions can be included within the deposition interface by clicking the "+" button at the bottom of the "Microscopy" page.
- Image recording. This section comprises information about the detector(s) or other device(s) used for image recording, including the both the physical properties of the detector and the manner in which the images were collected, e.g., data handling during and directly after capture, number of images, rate of movie frame collection, etc. As in the "Microscopy" section, the "+" can be used if multiple detectors were used for image recording.
- Reconstruction. This section comprises the details of the method or methods used to generate three-dimensional map(s) from two dimensional images, including particle selection, classification, alignment, angular assignment, and reconstruction. Information about multiple reconstructions can be included.
- Fitting interpretation. This section is for information about the fitting of pre-existing atomic coordinates and/or ab initio models to the map, if applicable. Multiple fitting instances can be added (by clicking the "+" button at the bottom of the page) and each instance can accommodate multiple starting models if necessary. Additional details that can be provided include software and settings for any model building, fitting, and/or refinement that was used to generate the final model.
Importing data in repeated depositions
When depositing a related structure, the OneDep File upload page offers Based on a previous wwPDB deposition. This lets you copy selected metadata from a previous wwPDB entry into your new deposition.
How to use it
- Open File upload in your deposition session at deposit.wwpdb.org.
- Under Based on a previous wwPDB deposition, select Yes.
- Enter the previous deposition ID (D_xxxxxxxxxx) and authenticate with the related entry's password, or sign in with ORCID if the entry is yours. The previous entry must be deposited at the same wwPDB site as the current entry.
- Select the metadata categories to import (for example authors, citation, funding, keywords, macromolecules, or method-specific experimental information).
- Upload your new coordinate, map, and/or data files, then process them as usual.
After processing, the Summary page shows which categories were imported, skipped, or blocked, with a detailed import log.
What can be imported
Typical categories include authors and contact information, entry keywords, citation information, funding information, macromolecules, and X-ray, NMR, or EM experimental information. Method-specific options appear only when the previous and current depositions use compatible experimental methods. For EM, the reconstruction sub-method must also match to import EM experimental information.
Coordinates, maps, and structure factors are not copied from the previous entry: you always upload new data files for the current deposition.